73-108-1MG6

Circuit Breakers

CIRCUIT BREAKER

73-108-1MG6

5925-00-951-5189

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Special Features

    circuit breaker will trip at 120 volts 75 miliseconds pole 1 only

  • Pole Quantity

    4

  • Frequency In Hertz

    400.0 all locations

  • Manual Actuator Type And Quantity

    4 toggle

  • Internal Trip Release Configuration

    relay trip first location

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Terminal Type And Quantity

    10 threaded stud

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct all locations and 80.000 maximum at 200 pct all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Internal Trip Release Configuration

    series trip fourth location

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Internal Trip Release Configuration

    series trip second location

  • Body Width

    3.000 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip third location

  • Mounting Surface To Terminal End Distance

    2.471 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Body Length

    2.500 inches nominal

  • Boss Height

    0.140 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.