1602320

Circuit Breakers

CIRCUIT BREAKER

1602320

5925-00-953-2094

5925 - Circuit Breakers

Lockheed Martin Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Switch Location And Position Designation

    internal at pole one

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Design Control Reference

    vp3he1a115v400cps69

  • Manufacturers Code

    74193

  • Terminal Type And Quantity

    2 tab, solder lug

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • ~1

    pct and 0.052 maximum at 400 pct single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.750 minimum at 125 pct and 5.000 maximum at 125 pct and 0.360 minimum at 150 pct and 1.850 maximum at 150 pct and 0.160 minimum at 200 pct and 0.600 maximum at 200 pct and 0.035 minimum at 300 pct and 0.170 maximum at 300 pct and 0.011 minimum at 400

  • Switch Terminal Type

    tab, solder lug

  • Switch Voltage Rating And Type In Volts

    125.0 ac

  • Frequency In Hertz

    400.0 single location

  • Case Material

    plastic

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    instantaneous and time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    500.0 single location

  • Ultimate Trip Time Per Pole In Seconds

    0.006 minimum and 0.028 maximum single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...