AP-12-3-51-151
Circuit Breakers
CIRCUIT BREAKER
AP-12-3-51-151
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc all locations
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Arc Quenching Method
magnetic blowout
-
Unpackaged Unit Weight
3.600 ounces
-
Body Length
1.562 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.610 inches minimum and 0.640 inches maximum
-
Thread Series Designator
unef
-
Body Width
1.281 inches maximum
-
Terminal Type And Quantity
6 wire hook
-
Inclosure Protection Type For Which Designed
hermetically sealed and shock resistant and vibration resistant
-
Bushing Length
0.380 inches maximum
-
Nonturn Device Diameter
0.235 inches minimum and 0.265 inches maximum
-
Nonturn Device Radius
0.610 inches minimum and 0.640 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.060 minimum at 200 pct all locations and 0.600 maximum at 200 pct all locations
-
Pole Quantity
2
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Thread Pitch Diameters
+0.3503/+0.3537 inches
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Mounting Surface To Terminal End Distance
1.780 inches maximum
-
Nonturn Device Location
at 3 oclock and at 9 oclock
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Center To Center Distance Between Terminals Parallel To Length
0.407 inches minimum and 0.469 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
150.0 milliamperes dc all locations
-
Internal Trip Release Configuration
shunt trip all locations
-
Actuator Position Designation
between pole one and two