382T6
Coils and Transformers
TRANSFORMER,POWER
382T6
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.875 inches nominal single mounting facility single center group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.675 inches nominal single mounting facility single center group
-
Frequency Rating
60.0 hertz nominal single component
-
Input-Output Phase Relationship
single phase to single phase single component
-
Body Width
0.594 inches nominal
-
Mounting Facility Quantity
4 single group
-
Winding Function And Quantity
1 primary single component and 1 secondary
-
Winding Operating Voltage
28.00 ac volts nominal single component single secondary
-
Terminal Type And Quantity
6 wire lead
-
Thread Class
2a single group
-
Thread Direction
right-hand single group
-
Reliability Indicator
not established
-
Maximum Transformer Power Rating
17.0 decibels single component
-
Body Length
0.688 inches nominal
-
Body Height
0.672 inches nominal
-
Inclosure Type
fully inclosed
-
Mounting Method
threaded stud single group
-
Thread Quantity Per Inch
40 single group
-
Nominal Thread Size
0.125 inches single group
-
Winding Tap Location
center tap single component single primary
-
Winding Tap Location
center tap single component single secondary
-
Winding Operating Voltage
126.00 ac volts nominal single component single primary
-
Thread Series Designator
unc single group