1323
Switches
SWITCH,PRESSURE
1323
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Adjustability
deactuation point not adjustable and actuation point adjustable, preset
-
Mounting Facility Pattern
two position in-line
-
Thread Quantity Per Inch
20 single pressure connection
-
Contact Action Stimulus
increase
-
Style Designator
cylindrical w/mounting lugs
-
Err Default
err default
-
Terminal Type
connector, receptacle
-
Unthreaded Mounting Hole Diameter
0.196 inches nominal
-
Contact Load Current Rating
4.0 amperes resistive load single voltage and 2.5 amperes inductive load single voltage
-
Contact Voltage Rating In Volts
30.0 dc at sea level single voltage
-
Distance Between Mounting Facility Centers
3.000 inches nominal
-
Mounting Method
flange and unthreaded hole
-
Overall Length
3.200 inches nominal
-
Contact Adjustment Range
+17.00/+29.00 actuation point pounds per square inch
-
Thread Class
3b single pressure connection
-
Contact Stimulus Rating
14.00 deactuation point nominal pounds per square inch gage
-
Pressure Connector Type
gasket seal, threaded internal single connection
-
Thread Series Designator
unf single pressure connection
-
Media For Which Designed
gas or liquid
-
Nominal Thread Size
0.454 inches single pressure connection
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 140.0 deg fahrenheit maximum
-
Body Diameter
1.800 nominal inches
-
Pressure Switch Type
gage