8938617-50

Circuit Breakers

CIRCUIT BREAKER

8938617-50

5925-00-958-6240

5925 - Circuit Breakers

Lockheed Martin Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant and corrosion resistant and moisture resistant

  • Terminal Type And Quantity

    2 wire hook

  • Body Style

    2a single pole type

  • Bushing Length

    0.375 inches maximum

  • Body Length

    1.500 inches maximum

  • Case Material

    metal

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Iii Arc Quenching Method

    magnetic blowout

  • Iii Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct and 0.800 maximum at 200 pct single location

  • Iii Unpackaged Unit Weight

    2.000 ounces

  • Thread Series Designator

    unef

  • Body Width

    0.625 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Iii Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    4.0 amperes dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...