XAM333MG3-30-208-14-400

Circuit Breakers

CIRCUIT BREAKER

XAM333MG3-30-208-14-400

5925-00-958-6242

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    2.219 inches minimum and 2.281 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.719 inches minimum and 0.781 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.032 inches minimum and 2.094 inches maximum

  • Mounting Surface To Terminal End Distance

    2.328 inches minimum and 2.390 inches maximum

  • Pole Quantity

    3

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Thread Pitch Diameters

    p0.118/p0.121 inches

  • Body Style

    multipole-multiple actuator type

  • Body Length

    2.469 inches minimum and 2.531 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.907 inches minimum and 1.969 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.094 inches minimum and 0.156 inches maximum

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    reset

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    8.000 minimum at 200 pct and 20.000 maximum at 200 pct

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

  • Actuator Position Designation

    at each pole

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Frequency In Hertz

    400.0

  • Unpackaged Unit Weight

    14.000 ounces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...