SM3-15AMP28VDCTDC57
Circuit Breakers
CIRCUIT BREAKER
SM3-15AMP28VDCTDC57
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
1.562 inches maximum
-
Body Width
0.625 inches maximum
-
Case Material
metal
-
Pole Quantity
1
-
Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes dc
-
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc
-
Trip Release Method
magnetic
-
Trip Release Characteristic
time delay
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Reset Method
manual
-
Body Style
single pole type
-
Bushing Length
0.375 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
0.885 inches maximum
-
Mounting Surface To Terminal End Distance
1.656 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
750.0 dc
-
Circuit Protection Type
overcurrent
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Terminal Type And Quantity
2 wire hook
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Position Designation
at pole one
-
Nominal Thread Size
0.375 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.100 minimum at 200 pct and 0.700 maximum at 200 pct
-
Unpackaged Unit Weight
2.100 ounces
-
Thread Series Designator
unef