AP-1-4-50-751
Circuit Breakers
CIRCUIT BREAKER
AP-1-4-50-751
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Special Handling Feature
magnetic
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
750.0 milliamperes dc
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc
-
Trip Release Method
magnetic
-
Trip Release Characteristic
instantaneouss
-
Ultimate Trip Time Per Pole In Seconds
0.035 nominal
-
Reset Method
manual
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole one
-
Nominal Thread Size
0.375 inches
-
Unpackaged Unit Weight
1.800 ounces
-
Terminal Type And Quantity
2 tab,solder lug and 2 wire hook
-
Bushing Length
0.380 inches maximum
-
Body Length
1.562 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
0.844 inches minimum and 0.906 inches maximum
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
1.605 inches maximum
-
Pole Quantity
1
-
Circuit Protection Type
overcurrent
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Thread Pitch Diameters
p0.3503/p0.3537 inches
-
Body Width
0.625 inches maximum
-
Case Material
metal
-
Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Internal Trip Release Configuration
relay trip
-
Inclosure Protection Type For Which Designed
shockproof and vibrationproof and hermetically sealed
-
Thread Series Designator
unef