Technical Characteristics

  • Body Length

    2.500 inches minimum and 2.530 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.930 inches minimum and 1.950 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Mounting Surface To Terminal End Distance

    2.408 inches minimum and 2.552 inches maximum

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 10.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip w/separate reset

  • Internal Trip Release Configuration

    series trip

  • Unpackaged Unit Weight

    0.280 pounds

  • Precious Material And Location

    terminals silver and nuts silver and washers silver

  • Precious Material

    silver

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 threaded stud

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes dc

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...