AM12MG6-50AMP50VDCTDC4
Circuit Breakers
CIRCUIT BREAKER
AM12MG6-50AMP50VDCTDC4
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
2.500 inches minimum and 2.530 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.930 inches minimum and 1.950 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Mounting Surface To Terminal End Distance
2.408 inches minimum and 2.552 inches maximum
-
Pole Quantity
1
-
Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
2 threaded hole
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc
-
Trip Release Characteristic
time delay
-
Reset Method
manual
-
Manual Actuator Type And Quantity
1 toggle
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 10.000 maximum at 200 pct
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Function
trip w/separate reset
-
Internal Trip Release Configuration
series trip
-
Unpackaged Unit Weight
0.280 pounds
-
Precious Material And Location
terminals silver and nuts silver and washers silver
-
Precious Material
silver
-
Thread Series Designator
unc
-
Terminal Type And Quantity
2 threaded stud
-
Body Width
0.740 inches minimum and 0.760 inches maximum
-
Case Material
plastic
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes dc
-
Circuit Protection Type
overcurrent
-
Trip Release Method
magnetic
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0