107-220-104
Circuit Breakers
CIRCUIT BREAKER
107-220-104
Wood Electric Operations Potter And
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Bushing Length
0.250 inches nominal
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Body Width
0.750 inches nominal
-
Actuator Function
trip-reset
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Mounting Surface To Terminal End Distance
1.812 inches nominal
-
Pole Quantity
1
-
Inclosure Protection Type For Which Designed
vibration resistant
-
Internal Trip Release Configuration
series trip single location
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac single location and 28.0 dc single location
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
400.0 single location
-
Body Length
1.094 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
0.704 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location and 6000.0 dc single location
-
Body Style
single pole type
-
Trip Delay Time In Seconds Per Rated Continuous Current
18.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location and 20.0 amperes dc single location
-
Terminal Type And Quantity
2 tab w/screw
-
Unpackaged Unit Weight
2.000 ounces
-
Nominal Thread Size
0.469 inches
-
Thread Series Designator
uns
-
Case Material
plastic