MP1660-375

Circuit Breakers

CIRCUIT BREAKER

MP1660-375

5925-00-964-7901

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    60.0 single location

  • Thread Series Designator

    unef

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 32.0 dc single location

  • Body Width

    0.560 inches nominal

  • Bushing Length

    0.500 inches nominal

  • Thread Quantity Per Inch

    28

  • Case Material

    plastic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    120.0 single location

  • Actuator Function

    reset

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct single location and 1.000 maximum at 200 pct single location

  • Storage Type

    general purpose warehouse

  • Inclosure Protection Type For Which Designed

    explosion resistant

  • Manual Actuator Type And Quantity

    1 push button

  • Body Length

    1.380 inches nominal

  • Nominal Thread Size

    0.438 inches

  • Maximum Continuous Load Current Rating Per Pole

    375.0 milliamperes ac single location and 375.0 milliamperes dc single location

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Mounting Surface To Terminal End Distance

    1.660 inches nominal

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    750.0 ac single location and 750.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Center To Center Distance Between Terminals Parallel To Length

    0.840 inches nominal

  • Terminal Type And Quantity

    2 tab, solder lug

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...