8938617-149

Circuit Breakers

CIRCUIT BREAKER

8938617-149

5925-00-964-9654

5925 - Circuit Breakers

Lockheed Martin Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.680 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    7.0 amperes ac single location

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant and hermetically sealed and corrosion resistant and moisture resistant

  • Operating Voltage Type And Rating Per Pole In Volts

    110.0 ac single location

  • Pole Quantity

    1

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct single location and 0.800 maximum at 200 pct single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Thread Series Designator

    unef

  • Body Width

    0.640 inches maximum

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Terminal Type And Quantity

    2 wire hook

  • Special Handling Feature

    magnetic

  • Center To Center Distance Between Terminals Parallel To Length

    0.594 inches minimum and 0.656 inches maximum

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac single location

  • Body Length

    1.750 inches maximum

  • Unpackaged Unit Weight

    2.000 ounces

  • Bushing Length

    0.380 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...