6752-14-2 1/2

Circuit Breakers

CIRCUIT BREAKER

6752-14-2 1/2

5925-00-967-6391

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Location And Position Designation

    internal at pole one

  • Auxiliary Switch Function And Quantity

    1 control

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.810 inches nominal

  • Bushing Length

    0.250 inches nominal

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 push button

  • Mounting Surface To Terminal End Distance

    2.370 inches nominal

  • Terminal Type And Quantity

    2 screw

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac single location and 2.5 amperes dc single location

  • Trip Release Method

    thermal single location

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 34.000 maximum at 200 pct single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.190 inches nominal

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Body Length

    2.189 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    4000.0 ac single location and 6000.0 dc single location

  • Body Width

    0.750 inches maximum

  • Trip Release Characteristic

    instantaneous single location and time delay single location

  • Operating Voltage Type And Rating Per Pole In Volts

    205.0 ac single location and 30.0 dc single location

  • Switch Terminal Type

    solder stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...