2098
Switches
SWITCH,ROTARY
2098
SWITCH,ROTARY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Hazardous Locations/Environmental Protection
explosion proof
-
Mounting Method
threaded bushing single mounting facility
-
Thread Quantity Per Inch
32 single mounting facility
-
Thread Class
2a single mounting facility
-
First Flat Length
0.310 inches nominal single actuator
-
Terminal Type
tab, solder lug
-
Pole Quantity
3 each section front
-
Nominal Thread Size
0.469 inches single mounting facility
-
Switch Contact Basic Design
nonpile-up symmetrical
-
Shaft Flat/Slot Angular Location
30.0 degrees from nonturn device single actuator
-
Shaft Length
0.765 inches nominal single actuator
-
Contact Load Current Rating
2.0 amperes resistive load ac at sea level
-
Throw Quantity
3 each section rear
-
Rotor Through Connection Quantity
1 each section
-
Contact Voltage Rating In Volts
28.0 dc at sea level
-
Switch Actuator Positioning Increment
30.0 degrees single actuator
-
Individual Section Quantity
16
-
Contact Load Current Rating
1.0 amperes resistive load dc at sea level
-
Overall Length
5.165 inches maximum
-
Switch Actuator Indexing Position Quantity
3 single actuator
-
Switch Actuator Stop Device Type
fixed stop single actuator
-
Thread Series Designator
uns single mounting facility
-
Contact Load Current Rating
500.0 milliamperes resistive load dc at altitude
-
Shaft Diameter
0.250 inches nominal single actuator
-
Overall Width
1.620 inches maximum
-
Contact Voltage Rating In Volts
115.0 ac at sea level
-
Style Designator
tap, circuit selector
-
Contact Switching Action
breaks before makes each section rear
-
Err Default
err default
-
Overall Height
2.700 inches maximum
-
Flat Height
0.210 inches nominal single actuator
-
Shaft Type
round, flatted single actuator
-
Special Features
two 1/4-20 unc-2a thd mtg studs on rear spaced 1.500 in. c to c
-
Nonturn Device Type
pin at 3:00 o'clock
-
Nonturn Device Radius
0.810 inches nominal at 3:00 o'clock