TA10
Coils and Transformers
TRANSFORMER,AUDIO FREQUENCY
TA10
TRANSFORMER,AUDIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency Rating
30.0 hertz minimum single component and 20.0 kilohertz maximum single component
-
Frequency Response Tolerance In Decibels (Non-Core)
-2.0/+2.0 single component
-
Impedance Rating In Ohms
4.0 nominal single component single secondary and 16.0 nominal single component single secondary
-
Winding Tap Location (Non-Core)
center tap single component single primary
-
Body Length
1.562 inches nominal
-
Distance Between Mounting Facility Centers
1.375 inches nominal single mounting facility single center group
-
Terminal Type And Quantity
7 wire lead
-
Maximum Transformer Power Rating
200.0 milliwatts single component
-
Inclosure Type
open
-
Body Width
0.750 inches nominal
-
Mounting Facility Quantity
2 single group
-
Winding Tap Location (Non-Core)
tap w/center tap single component single secondary
-
Mounting Method
flange single group and unthreaded hole single group
-
Impedance Rating In Ohms
2000.0 nominal single component single primary
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Body Height
0.750 inches nominal
-
Reliability Indicator
not established