25-14800A05
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
25-14800A05
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Length
0.820 inches nominal
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function and 400.0 volts dc 1st radio interference 1st function
-
Inclosure Type
encased
-
Functional Terminal Type And Quantity
1 tab, solder lug input 1st function
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Body Length
0.470 inches nominal
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Temp Range
-55.0/+85.0 deg celsius
-
Style Designator
round terminal/terminals on opposite surfaces
-
Maximum Voltage Drop Per Function
120.0 millivolts dc 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Maximum Voltage Drop Per Function
120.0 millivolts dc 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Maximum Voltage Drop Per Function
120.0 millivolts dc 4th radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function and 400.0 volts dc 2nd radio interference 2nd function
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 4th radio interference
-
Operating Current Rating Per Function In Amps
1.5 1st radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance blank
-
Functional Terminal Type And Quantity
1 tab, solder lug output 2nd function
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 4th radio interference 4th function and 400.0 volts dc 4th radio interference 4th function
-
Operating Current Rating Per Function In Amps
1.5 2nd radio interference
-
Operating Current Rating Per Function In Amps
1.5 3rd radio interference
-
Operating Current Rating Per Function In Amps
1.5 4th radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference 3rd function and 400.0 volts dc 3rd radio interference 3rd function
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Nominal Thread Size
0.138 inches
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Mounting Facility Screw Thread Series Designator
unc
-
Body Outside Diameter
0.188 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Maximum Voltage Drop Per Function
120.0 millivolts dc 1st radio interference