905121-1
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
905121-1
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Operating Current Rating Per Function In Amps
0.75 1st radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Style Designator
rectangular terminal/terminals on adjacent surfaces
-
Operating Current Rating Per Function In Amps
0.75 2nd radio interference
-
Overall Width
1.665 inches maximum
-
Operating Temp Range
-55.0/+95.0 deg celsius
-
Operating Current Rating Per Function In Amps
0.75 3rd radio interference
-
Overall Length
1.985 inches minimum and 2.015 inches maximum
-
Body Material
metal
-
Full Load Minimum Insertion Loss At Specified Frequency In Decibels
60.0 and 70.0 and 50.0 and 20.0 and 80.0 and 60.0
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Maximum Voltage Drop Per Function
400.0 millivolts ac 2nd radio interference
-
Full Load Insertion Loss Frequencies In Megahertz
1.0 and 5.0 and 0.5 and 0.1 and 10.0 and 20.0
-
Operating Voltage Rating And Type Per Function
28.0 volts ac 2nd radio interference 2nd function
-
Body Length
1.510 inches nominal
-
Unthreaded Mounting Hole Diameter
0.141 inches minimum and 0.155 inches maximum
-
Input Terminal Manufacturer Code
20093
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Mounting Facility Type And Quantity
12 terminal
-
Maximum Voltage Drop Per Function
400.0 millivolts ac 3rd radio interference
-
Inclosure Type
hermetically sealed
-
Output Terminal Manufacturer Code
20093
-
Output Terminal Identification
aaas-60t-l4x
-
Functional Terminal Type And Quantity
3 tab, solder lug input 1st function
-
Input Terminal Identification
aaas-60t-l4x
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Voltage Rating And Type Per Function
28.0 volts ac 3rd radio interference 3rd function
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.250 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Operating Voltage Rating And Type Per Function
28.0 volts ac 1st radio interference 1st function
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Maximum Temp Rise
30.0 deg celsius
-
Mounting Facility Type And Quantity
3 unthreaded hole
-
Power Line Frequency Rating Per Function In Hertz
420.0 1st radio interference
-
Functional Terminal Type And Quantity
3 tab, solder lug output 2nd function
-
Overall Height
0.590 inches maximum
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
420.0 2nd radio interference
-
Body Width
1.485 inches minimum and 1.515 inches maximum
-
Vibration Resistance Range In Hertz
+10.0/+500.0
-
Unpackaged Unit Weight
5.000 ounces
-
Power Line Frequency Rating Per Function In Hertz
420.0 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.750 inches nominal