SM33-7-5-240VAC400C2

Circuit Breakers

CIRCUIT BREAKER

SM33-7-5-240VAC400C2

5925-00-978-4408

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Nominal Thread Size

    0.375 inches

  • Frequency In Hertz

    400.0

  • Unpackaged Unit Weight

    3.400 ounces

  • Precious Material And Location

    contacts silver

  • Precious Material

    silver

  • Thread Series Designator

    unef

  • Body Style

    multipole-single actuator type

  • Bushing Length

    0.375 inches nominal

  • Body Width

    1.250 inches maximum

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac

  • Circuit Protection Type

    overcurrent

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.190 minimum at 200 pct and 0.700 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    explosion resistant and fungus resistant and hermetically sealed

  • Terminal Type And Quantity

    4 wire hook

  • Body Length

    1.500 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    2

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    between pole one and two

  • Internal Trip Release Configuration

    series trip

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...