Technical Characteristics

  • Body Length

    2.485 inches minimum and 2.515 inches maximum

  • Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.047 inches minimum and 2.077 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Iii Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.775 inches minimum and 2.955 inches maximum

  • Pole Quantity

    1

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Iii Storage Type

    general purpose warehouse

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac and 3.0 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac and 2000.0 dc single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant and moisture resistant and salt spray proof

  • Switch Voltage Rating And Type In Volts

    115.0 ac and 50.0 dc

  • Test Data Document

    05869-711570 drawing

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 threaded stud

  • Body Style

    12a single pole type

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Boss Height

    0.125 inches minimum and 0.155 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac and 50.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct and 10.000 maximum at 200 pct single location

  • Switch Terminal Type

    tab, solder lug

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Frequency In Hertz

    400.0 single location

  • Iii Unpackaged Unit Weight

    0.312 pounds

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...