GA53603L5
Circuit Breakers
CIRCUIT BREAKER
GA53603L5
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency In Hertz
400.0
-
Nominal Thread Size
0.138 inches
-
Manual Actuator Type And Quantity
1 toggle
-
Reset Method
manual
-
Trip Release Characteristic
time delay
-
Terminal Type And Quantity
2 threaded stud
-
Thread Series Designator
unc
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.500 minimum at 200 pct and 8.000 maximum at 200 pct
-
Actuator Function
reset
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0
-
Trip Release Method
magnetic
-
Circuit Protection Type
overcurrent
-
Mounting Facility Type And Quantity
2 threaded hole
-
Case Material
plastic
-
Overall Height
0.750 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac
-
Thread Quantity Per Inch
32
-
Arc Quenching Method
air
-
Pole Quantity
1
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
-
Overall Width
2.500 inches nominal
-
Overall Length
3.375 inches nominal