77-101-41

Circuit Breakers

CIRCUIT BREAKER

77-101-41

5925-00-979-9077

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    2 wire hook

  • Precious Material

    silver

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed and moisture resistant

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac single location

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Pole Quantity

    1

  • Case Material

    metal

  • Body Length

    1.562 inches maximum

  • Bushing Length

    0.380 inches maximum

  • Precious Material And Location

    contact surfaces silver

  • Unpackaged Unit Weight

    2.100 ounces

  • Frequency In Hertz

    400.0 single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.070 minimum at 200 pct single location and 0.700 maximum at 200 pct

  • Nominal Thread Size

    0.375 inches

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    230.0 ac single location

  • Special Handling Feature

    magnetic

  • Mounting Surface To Terminal End Distance

    1.656 inches maximum

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    0.594 inches minimum and 0.656 inches maximum

  • Body Width

    0.652 inches maximum

  • Body Style

    2a single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...