FC215-450
Relays and Solenoids
RELAY,ELECTROMAGNETIC
FC215-450
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
data on certain environmental and performance
-
Mounting Facility Type And Quantity
2 slotted hole single mounting facility
-
Winding Quantity
1
-
Overall Width
0.625 inches maximum
-
Terminal Type And Quantity
8 wire hook all functions
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Environmental Protection
hermetic and shock resistant and vibration resistant
-
Winding Dc Resistance Rating
270.0 ohms minimum single winding and 330.0 ohms maximum single winding
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.437 inches nominal single mounting facility
-
Cubic Measure
1.763 cubic inches
-
Coil Quantity
1
-
Overall Length
1.750 inches maximum
-
Duty Type
continuous
-
Mounting Facility Pattern
in-line single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
500.0 milliamperes ac lamp load and 1.0 amperes dc lamp load
-
Main Contact Load Current Rating At Maximum Rated Voltage
1.5 amperes ac motor load and 3.0 amperes dc motor load
-
Specification/Standard Data
81349-mil-r-5757/23 government specification
-
Mounting Slot Width
0.500 inches maximum single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
3.0 amperes ac resistive load and 10.0 amperes dc resistive load
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Overall Height
1.612 inches maximum
-
Time Delay
0.015 seconds maximum fixed operate and release time
-
Operating Voltage Rating And Type At Specified Temp
26.5 volts dc 25 deg celsius single winding
-
Test Data Document
81349-mil-r-5757 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type