555264-004

Circuit Breakers

CIRCUIT BREAKER

555264-004

5925-00-981-5309

5925 - Circuit Breakers

Bae Systems National Security

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Bushing Length

    0.280 inches minimum and 0.380 inches maximum

  • Reset Method

    manual

  • Internal Trip Release Configuration

    relay trip single location

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Unpackaged Unit Weight

    2.100 ounces

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Terminal Type And Quantity

    4 wire hook

  • Pole Quantity

    1

  • Case Material

    metal

  • Maximum Continuous Load Current Rating Per Pole

    600.0 milliamperes ac single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Precious Material And Location

    contact surfaces silver

  • Body Length

    1.562 inches maximum

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Body Width

    0.625 inches maximum

  • Trip Release Method

    magnetic-hydraulic single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Thread Series Designator

    unef

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct single location and 0.950 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...