7274-12-5

Circuit Breakers

CIRCUIT BREAKER

7274-12-5

5925-00-982-9657

5925 - Circuit Breakers

Seabrook Shipyard

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Nonturn Device Length

    0.078 inches nominal

  • Body Length

    0.750 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    800.0 ac single location and 2000.0 dc single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Thread Series Designator

    un

  • Case Material

    plastic

  • Inclosure Protection Type For Which Designed

    corrosion resistant and sandtight and shockproof

  • Fragility Factor

    moderately rugged

  • Bushing Length

    0.250 inches nominal

  • Nonturn Device Radius

    0.388 inches nominal

  • Reset Method

    manual

  • Body Width

    0.562 inches maximum

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Nonturn Device Width

    0.110 inches nominal

  • Unpackaged Unit Weight

    1.500 ounces

  • Nonturn Device Location

    at 12 oclock

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Arc Quenching Method

    air

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Mounting Surface To Terminal End Distance

    1.707 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    0.703 inches nominal

Related Parts by Manufacturer

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...