BACC18G-50

Circuit Breakers

CIRCUIT BREAKER

BACC18G-50

5925-00-984-9576

5925 - Circuit Breakers

The Boeing Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Inclosure Protection Type For Which Designed

    corrosion resistant and explosion proof and dustproof and fungus resistant

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.158 inches minimum and 1.218 inches maximum

  • Unpackaged Unit Weight

    160.000 pounds

  • Manual Actuator Type And Quantity

    1 push-pull

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct single location and 60.000 maximum at 200 pct single location

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Body Length

    2.188 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac single location and 50.0 amperes dc single location

  • Special Handling Feature

    magnetic

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac single location and 28.0 dc single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Bushing Length

    0.235 inches minimum and 0.250 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.807 inches minimum and 1.817 inches maximum

  • Body Width

    0.750 inches maximum

  • Trip Release Characteristic

    instantaneous single location and time delay single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 5000.0 dc single location

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...