10-30108-35

Circuit Breakers

CIRCUIT BREAKER

10-30108-35

5925-00-985-8269

5925 - Circuit Breakers

The Boeing Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-c-27715 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performanc

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Nominal Thread Size

    0.138 inches

  • Body Length

    2.189 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    26.000 minimum at 200 pct single location and 53.000 maximum at 200 pct single location

  • Pole Quantity

    1

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.800 inches minimum and 1.820 inches maximum

  • Manual Actuator Type And Quantity

    1 push-pull

  • Unpackaged Unit Weight

    0.200 pounds

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Specification/Standard Data

    96906-ms24571 government standard

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Mounting Surface To Terminal End Distance

    2.370 inches nominal

  • Body Width

    0.760 inches maximum

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    relay trip single location

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Special Handling Feature

    magnetic

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

  • Case Material

    plastic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 5000.0 dc single location

  • Inclosure Protection Type For Which Designed

    sandtight and salt spray proof and explosion proof and shock resistant and dusttight and vaportight and humidity proof and fungus proof

  • Terminal Type And Quantity

    3 tab w/screw

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac single location and 35.0 amperes dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Bushing Length

    0.187 inches minimum and 0.249 inches maximum

  • Trip Release Characteristic

    time delay single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.190 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...