9224-4488
Relays and Solenoids
RELAY,ELECTROMAGNETIC
9224-4488
Leach International Corporation
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Fragility Factor
moderately rugged
-
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac motor load and 4.0 amperes dc motor load
-
Overall Width
1.531 inches maximum
-
Mounting Facility Type And Quantity
3 unthreaded hole single mounting facility
-
Storage Type
general purpose warehouse
-
Specification/Standard Data
96906-ms25327 government standard
-
Operating Voltage Rating And Type At Specified Temp
115.0 volts ac 25 deg celsius single winding
-
~1
data on certain environmental and performance
-
Environmental Protection
hermetic
-
Arc Quenching Method
air
-
Main Contact Load Current Rating At Maximum Rated Voltage
6.0 amperes ac inductive load and 6.0 amperes dc inductive load
-
Winding Quantity
1
-
Unthreaded Mounting Hole Diameter
0.147 inches nominal single mounting facility
-
Case Material
metal
-
Frequency In Hertz
400.0 nominal
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
-
Cubic Measure
7.219 cubic inches
-
Mounting Facility Pattern
triangle single mounting facility
-
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
1.844 inches nominal single mounting facility
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Overall Height
2.156 inches maximum
-
Nonpile-Up Main Contact Arrangement
4 pole, double throw, one position momentary
-
Purpose For Which Designed
general
-
Coil Quantity
1
-
Terminal Type And Quantity
14 pin all functions
-
Overall Length
2.187 inches maximum
-
Time Delay
0.05 seconds maximum fixed release time
-
Duty Type
continuous
-
Time Delay
0.02 seconds maximum fixed operate time
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load