AM333MG6-27-250-400-15

Circuit Breakers

CIRCUIT BREAKER

AM333MG6-27-250-400-15

5925-00-988-4368

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    400.0 all locations

  • Iii Unpackaged Unit Weight

    11.100 ounces

  • Mounting Surface To Terminal End Distance

    2.475 inches nominal

  • Iii Arc Quenching Method

    magnetic blowout

  • Iii Storage Type

    general purpose warehouse

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    27.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 22.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and salt spray proof and shock resistant and vibration resistant

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

  • Body Style

    8c multipole-multiple actuator type

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Iii Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Boss Height

    0.150 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Thread Pitch Diameters

    0.1177 to 0.1214 inches

  • Body Width

    2.250 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...