SAJ12505
Coils and Transformers
TRANSFORMER,POWER
SAJ12505
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Method
threaded stud single group
-
Thread Quantity Per Inch
32 single group
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Winding Operating Voltage
6.30 ac volts nominal single component 2nd secondary
-
Body Length
1.625 inches nominal
-
Overall Height
2.375 inches nominal
-
Mounting Facility Quantity
4 single group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.188 inches nominal single mounting facility single center group
-
Terminal Type And Quantity
6 feed thru
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Overall Width
1.625 inches nominal
-
Maximum Operating Temp
70.0 deg celsius
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.188 inches nominal single mounting facility single center group
-
Winding Operating Voltage
6.00 ac volts nominal single component 1st secondary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Winding Shielding Method
internal shield grounded to core single component
-
Inclosure Type
hermetically sealed
-
Thread Series Designator
unc single group
-
Winding Operating Current
650.0 milliamperes ac maximum single component 1st secondary
-
Thread Direction (Non-Core)
err-070
-
Nominal Thread Size
0.138 inches single group
-
Winding Operating Current
3.0 amperes ac maximum single component 2nd secondary