SM3-0R5-50-58

Circuit Breakers

CIRCUIT BREAKER

SM3-0R5-50-58

5925-00-991-2090

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    2a single pole type

  • Bushing Length

    0.360 inches minimum and 0.380 inches maximum

  • Body Length

    1.448 inches minimum and 1.510 inches maximum

  • Mounting Surface To Terminal End Distance

    1.524 inches minimum and 1.586 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc single location

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.375 inches

  • Iii Unpackaged Unit Weight

    2.100 ounces

  • Body Width

    0.567 inches minimum and 0.629 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.870 inches minimum and 0.880 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Iii Storage Type

    general purpose warehouse

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct and 0.450 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    2 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...