Technical Characteristics
-
Style Designator
circular wafer, bushing mount
-
Thread Class
2a 1st mounting facility
-
Flat Height
0.218 inches nominal single actuator
-
Contact Switching Action
makes before breaks 3rd section rear
-
Overall Height
1.312 inches nominal
-
Mounting Method
threaded bushing 1st mounting facility
-
Err Default
err default
-
Mounting Facility Pattern
two position in-line 2nd mounting facility
-
Precious Material
silver
-
Throw Quantity
10 8th section front
-
Thread Class
2a 2nd mounting facility
-
Mounting Method
threaded stud 2nd mounting facility
-
Throw Quantity
10 9th section front
-
Shaft Type
round, flatted single actuator
-
Individual Section Quantity
9
-
Overall Length
13.906 inches nominal
-
Precious Material And Location
contacts and rotor blade surfaces silver
-
Contact Switching Action
makes before breaks 5th section front
-
Switch Actuator Indexing Position Quantity
12 single actuator
-
Thread Series Designator
unc 2nd mounting facility
-
Contact Switching Action
makes before breaks 5th section rear
-
Nonturn Device Type
tab at 3:00 o'clock
-
Shaft Length
1.000 inches nominal single actuator
-
Nonturn Device Radius
0.531 inches nominal at 3:00 o'clock
-
Terminal Type
tab, solder lug
-
Shaft Flat/Slot Angular Location
90.0 degrees from nonturn device single actuator
-
Contact Voltage Rating In Volts
110.0 ac at sea level
-
Overall Width
1.250 inches nominal
-
Contact Switching Action
makes before breaks 7th section front
-
Contact Switching Action
breaks before makes 1st section front
-
Nominal Thread Size
0.375 inches 1st mounting facility
-
Switch Actuator Stop Device Type
adjustable stop single actuator
-
Pole Quantity
1 8th section front
-
Longest Horizontal Distance Between Mounting Centers
1.250 inches nominal 2nd mounting facility
-
Throw Quantity
10 1st section front
-
First Flat Length
0.375 inches nominal single actuator
-
Contact Switching Action
makes before breaks 7th section rear
-
Contact Switching Action
breaks before makes 8th section front
-
Contact Voltage Rating In Volts
28.0 dc at sea level
-
Switch Contact Basic Design
nonpile-up symmetrical and nonpile-up nonsymmetrical
-
Thread Quantity Per Inch
32 1st mounting facility
-
Pole Quantity
1 1st section front
-
Nominal Thread Size
0.112 inches 2nd mounting facility
-
Pole Quantity
1 9th section front
-
Contact Switching Action
breaks before makes 9th section front
-
Switch Actuator Positioning Increment
30.0 degrees single actuator
-
Contact Load Current Rating
1.0 amperes resistive load dc at sea level
-
Shaft Diameter
0.250 inches nominal single actuator
-
Thread Series Designator
unef 1st mounting facility
-
Contact Load Current Rating
500.0 milliamperes resistive load ac at sea level
-
Thread Quantity Per Inch
40 2nd mounting facility
-
Contact Switching Action
makes before breaks 3rd section front