MP1501AC
Circuit Breakers
CIRCUIT BREAKER
MP1501AC
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
1.859 inches maximum
-
Mounting Facility Type And Quantity
1 threaded hole
-
Thread Series Designator
unc
-
Reset Method
manual
-
Inclosure Protection Type For Which Designed
explosion proof and vibrationproof
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.400 minimum at 200 pct single location and 1.800 maximum at 200 pct single location
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Body Width
0.672 inches minimum and 0.702 inches maximum
-
Pole Quantity
1
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location and 5000.0 dc single location
-
Case Material
plastic
-
Bushing Length
0.250 inches maximum
-
Test Data Document
81205-bacc18k drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.807 inches minimum and 1.817 inches maximum
-
Terminal Type And Quantity
2 tab w/screw
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Body Length
2.187 inches maximum
-
Body Style
single pole type
-
Frequency In Hertz
400.0 single location
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac single location and 1.0 amperes dc single location
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Trip Release Characteristic
time delay single location
-
Center To Center Distance Between Terminals Parallel To Length
0.655 inches minimum and 0.685 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac single location and 28.0 dc single location