GF-6902

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

GF-6902

5915-00-993-2797

5915 - Filters and Networks

Genisco Filter Corp.

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 5th radio interference 5th function

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 6th radio interference 6th function

  • Output Terminal Manufacturer Code

    20093

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Output Terminal Identification

    aaas-60t-l4x

  • Test Data Document

    06481-905124-1 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Full Load Insertion Loss Frequencies In Megahertz

    0.3 and 1.0 and 2.0 and 10.0 and 5.0 and 20.0

  • Input Terminal Identification

    aaas-60t-l4x

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.062 inches nominal

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 1st radio interference 1st function

  • Operating Current Rating Per Function In Amps

    0.8 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Operating Current Rating Per Function In Amps

    0.8 3rd radio interference

  • Body Height

    0.500 inches nominal

  • Operating Current Rating Per Function In Amps

    0.8 4th radio interference

  • Mounting Facility Screw Thread Series Designator

    unc

  • Nominal Thread Size

    0.112 inches

  • Operating Current Rating Per Function In Amps

    0.8 5th radio interference

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 2nd radio interference 2nd function

  • Operating Current Rating Per Function In Amps

    0.8 6th radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.625 inches nominal

  • Input Terminal Manufacturer Code

    20093

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 3rd radio interference 3rd function

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 4th radio interference 4th function

  • Functional Terminal Type And Quantity

    6 tab, solder lug output 2nd function

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Inclosure Type

    hermetically sealed

  • Full Load Minimum Insertion Loss At Specified Frequency In Decibels

    10.0 and 70.0 and 50.0 and 45.0 and 30.0 and 30.0

  • Overall Height

    0.650 inches nominal

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Body Width

    1.440 inches nominal

  • Body Length

    2.000 inches nominal

  • Body Surface Treatment

    tin

  • Maximum Voltage Drop Per Function

    300.0 millivolts dc 1st radio interference

  • Operating Temp Range

    -55.0/+95.0 deg celsius

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Body Material

    metal

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Maximum Voltage Drop Per Function

    300.0 millivolts dc 2nd radio interference

  • Maximum Temp Rise

    30.0 deg celsius

  • Maximum Voltage Drop Per Function

    300.0 millivolts dc 3rd radio interference

  • Style Designator

    rectangular terminal/terminals on one surface

  • Maximum Voltage Drop Per Function

    300.0 millivolts dc 4th radio interference

  • Functional Terminal Type And Quantity

    6 tab, solder lug input 1st function

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Maximum Voltage Drop Per Function

    300.0 millivolts dc 5th radio interference

  • Maximum Voltage Drop Per Function

    300.0 millivolts dc 6th radio interference

  • Vibration Resistance Range In Hertz

    +10.0/+500.0

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Unpackaged Unit Weight

    6.000 ounces

  • Operating Current Rating Per Function In Amps

    0.8 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...