AM33DRKMG6-20-40-230-115VAC60C4

Circuit Breakers

CIRCUIT BREAKER

AM33DRKMG6-20-40-230-115VAC60C4

5925-00-994-0400

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    2 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one and two linked

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Thread Series Designator

    unc

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Boss Height

    0.140 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac

  • Circuit Protection Type

    overcurrent

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct and 12.000 maximum at 200 pct

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    4 threaded stud

  • Body Length

    2.500 inches nominal

  • Body Width

    1.500 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Mounting Surface To Terminal End Distance

    2.471 inches nominal

  • Pole Quantity

    2

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac

  • Operating Voltage Type And Rating Per Pole In Volts

    230.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Time Per Pole In Seconds

    18.000 minimum and 90.000 maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...