114-205-101

Circuit Breakers

CIRCUIT BREAKER

114-205-101

5925-00-994-6602

5925 - Circuit Breakers

Wood Electric Operations Potter And

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 30.000 maximum at 200 pct single location

  • Boss Height

    0.125 inches nominal

  • Frequency In Hertz

    400.0 single location

  • Overall Length

    1.344 inches nominal

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    1.656 inches nominal

  • Switch Current Rating And Type In Amps

    3.0 ac and 1.0 dc

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location and 32.0 dc single location

  • Switch Terminal Type

    pin

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Unpackaged Unit Weight

    3.000 ounces

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Terminal Type And Quantity

    2 screw base

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Arc Quenching Method

    air

  • Manual Actuator Type And Quantity

    1 push-pull

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.000 inches nominal

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    200.0 ac single location and 300.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Overall Width

    0.993 inches nominal

  • Mounting Surface To Terminal End Distance

    1.875 inches nominal

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.