CB3700A5

Circuit Breakers

CIRCUIT BREAKER

CB3700A5

5925-00-994-6602

5925 - Circuit Breakers

Tyco Electronics Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 30.000 maximum at 200 pct single location

  • Boss Height

    0.125 inches nominal

  • Frequency In Hertz

    400.0 single location

  • Overall Length

    1.344 inches nominal

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    1.656 inches nominal

  • Switch Current Rating And Type In Amps

    3.0 ac and 1.0 dc

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location and 32.0 dc single location

  • Switch Terminal Type

    pin

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Unpackaged Unit Weight

    3.000 ounces

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Terminal Type And Quantity

    2 screw base

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Arc Quenching Method

    air

  • Manual Actuator Type And Quantity

    1 push-pull

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.000 inches nominal

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    200.0 ac single location and 300.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Overall Width

    0.993 inches nominal

  • Mounting Surface To Terminal End Distance

    1.875 inches nominal

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...