20800-236

Coils and Transformers

TRANSFORMER,POWER

20800-236

5950-00-996-1015

5950 - Coils and Transformers

Hickok Incorporated

TRANSFORMER,POWER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Reliability Indicator

    not established

  • Overall Length

    1.687 inches nominal

  • Overall Height

    1.375 inches nominal

  • Frequency Rating

    60.0 hertz nominal

  • Body Length

    1.687 inches nominal

  • Body Height

    1.375 inches nominal

  • Distance Between Mounting Facility Centers

    1.688 inches nominal

  • Inclosure Type

    open

  • Mounting Facility Quantity

    2

  • Mounting Method

    unthreaded hole

  • Winding Operating Current

    125.0 milliamperes ac maximum

  • Winding Operating Voltage

    115.00 ac volts nominal

  • Winding Operating Voltage

    25.00 ac volts nominal

  • Terminal Type And Quantity

    4 wire lead

  • Overall Width

    1.250 inches nominal

  • Mounting Hole Diameter

    0.187 inches nominal

  • Input-Output Phase Relationship

    single phase to single phase

  • Body Width

    1.250 inches nominal

  • Winding Function And Quantity

    1 primary and 1 secondary