D6761-2-7
Circuit Breakers
CIRCUIT BREAKER
D6761-2-7
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Release Ambient Temp Rating
77.0 deg fahrenheit nominal all locations
-
Inclosure Protection Type For Which Designed
explosion proof
-
Main Contact Tripping Mechanism Type
trip free
-
Bushing Length
0.469 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac all locations and 7.5 amperes dc all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
-
Frequency In Hertz
400.0 all locations
-
Body Length
0.750 inches maximum
-
Body Width
2.188 inches maximum
-
Unpackaged Unit Weight
2.000 ounces
-
Nominal Thread Size
0.469 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
40.000 minimum at 200 pct all locations and 100.000 maximum at 200 pct all locations
-
Thread Series Designator
uns
-
Case Material
plastic
-
Trip Release Method
thermal all locations
-
Pole Quantity
2
-
Reset Method
manual
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Length
0.594 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations and 30.0 dc all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac all locations and 4000.0 dc all locations
-
Terminal Type And Quantity
4 screw
-
Center To Center Distance Between Terminals Parallel To Width
0.188 inches nominal
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Manual Actuator Type And Quantity
1 push-pull
-
Body Style
multipole-single actuator type
-
Test Data Document
11871-7260-804-3 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Body Height
2.188 inches nominal
-
Circuit Protection Type
overcurrent all locations