Technical Characteristics

  • Body Style

    32b rectangular w/mounting holes

  • Reliability Indicator

    not established

  • Overall Length

    0.530 inches nominal

  • Center To Center Distance Between Terminal Rows

    0.100 inches nominal

  • Rotary Actuator Travel In Angular Deg

    7200.0 minimum and 16200.0 maximum

  • Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius

    -70.0/+70.0 single section

  • Power Dissipation Rating Per Section In Watts

    0.5 free air single section

  • Resistance Tolerance Per Section In Percent

    -5.0/+5.0 single section

  • Actuator Travel Control Feature

    clutch

  • Ambient Temp In Deg Celsius Per Section At Full Rated Power

    85.0 single section

  • Standard Taper Curve Per Section

    a single section

  • Test Data Document

    15786-83289 drawing

  • Terminal Type And Quantity

    3 pin

  • Section Quantity

    1

  • Terminal Length

    0.500 inches minimum

  • Shaft Diameter

    0.060 inches minimum and 0.100 inches maximum

  • Shaft Length

    0.020 inches minimum and 0.040 inches maximum

  • Body Length

    0.490 inches minimum and 0.510 inches maximum

  • Shaft Style

    3c round, slotted

  • Actuator Type

    single shaft

  • Effective Electrical Rotation In Deg Angular Rotation

    7200.0 minimum and 16200.0 maximum

  • Center To Center Distance Between Terminals

    0.200 inches nominal

  • Fragility Factor

    moderately rugged

  • Terminal Location

    right adjacent side two rows

  • Mounting Method

    terminal and unthreaded hole

  • Overall Height

    0.490 inches minimum and 0.510 inches maximum

  • Overall Width

    0.720 inches nominal

  • Mounting Hole Diameter

    0.068 inches minimum and 0.088 inches maximum

  • Body Width

    0.210 inches minimum and 0.230 inches maximum

  • Body Height

    0.490 inches minimum and 0.510 inches maximum

  • Maximum Starting Torque

    5.00 inch-ounces (ounce-inches)

  • Maximum Running Torque

    5.00 inch-ounces (ounce-inches)

  • Lateral Distance Between Mounting Hole Centers

    0.510 inches minimum and 0.530 inches maximum

  • Mounting Facility Quantity

    2

  • Cubic Measure

    0.055 cubic inches

  • Electrical Resistance Per Section

    10.0 kilohms single section

  • Center To Center Distance Between Center Terminal And Outside Terminal

    0.100 inches nominal

  • Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power

    150.0 single section

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...