AC8369-11
Coils and Transformers
COIL,RADIO FREQUENCY
AC8369-11
COIL,RADIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Distance Between Mounting Facility Centers
0.390 inches minimum single mounting facility single center group and 0.410 inches maximum single mounting facility single center group
-
Rating Method
electrical single component single winding
-
Dummy Terminal Quantity (Non-Core)
2
-
Winding Operating Current
900.0 milliamperes maximum of standard range b and better drop siding single component single winding
-
Terminal Type And Quantity
2 pin
-
Frequency At Which Inductance And Quality Factor Applies (Non-Core)
25.0 megahertz single component single winding
-
Overall Width
0.397 inches minimum and 0.417 inches maximum
-
Core Construction
s0lid single component
-
Quality Factor
65 minimum single component single winding and 70 maximum single component single winding
-
Mounting Method
tab single group
-
Overall Length
0.397 inches minimum and 0.417 inches maximum
-
Coil Form Type
hollow single component
-
Inductance Rating
0.62 microhenries minimum single component single winding and 0.74 microhenries maximum single component single winding
-
Minimum Self-Resonant Frequency (Non-Core)
175.0 megahertz single component
-
Inclosure Type
fully inclosed
-
Mounting Tab Width
0.047 inches minimum and 0.053 inches maximum
-
Dc Resistance Rating In Ohms
0.200 single component single winding
-
Body Height
0.315 inches minimum and 0.355 inches maximum
-
Maximum Operating Temp
125.0 deg celsius
-
Reliability Indicator
not established
-
Test Data Document
96214-800743 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Adjustment Device Drive Type
slotted screw single component
-
Adjustment Method And Quantity
1 adjustable core single component