52-353-001
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
52-353-001
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Mounting Facility Screw Thread Series Designator
unc
-
Functional Terminal Type And Quantity
3 tab, solder lug input .
-
Functional Terminal Type And Quantity
3 tab, solder lug output .
-
Operating Voltage Rating And Type Per Function
240.0 volts ac 3rd radio interference .
-
Nominal Thread Size
0.112 inches
-
Overall Length
2.900 inches maximum
-
Overall Width
1.800 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference .
-
Load Impedance Per Function
50.0 ohms 1st radio interference .
-
Operating Current Rating Per Function In Amps
3.0 1st radio interference .
-
Operating Current Rating Per Function In Amps
3.0 2nd radio interference .
-
Operating Current Rating Per Function In Amps
3.0 3rd radio interference .
-
Overall Height
0.800 inches nominal
-
Body Length
2.900 inches maximum
-
Body Width
1.400 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.000 inches nominal
-
Operating Temp Range
-55.0/+125.0 deg celsius
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference .
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference .
-
Load Impedance Per Function
50.0 ohms 2nd radio interference .
-
Load Impedance Per Function
50.0 ohms 3rd radio interference .
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference .
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference .
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference .
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Inclosure Type
encased
-
Mounting Facility Type And Quantity
4 threaded hole
-
Operating Voltage Rating And Type Per Function
240.0 volts ac 1st radio interference .
-
Operating Voltage Rating And Type Per Function
240.0 volts ac 2nd radio interference .
-
Style Designator
1 rectangular terminal/terminals on opposite surfaces