325075-6

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

325075-6

5915-01-005-9637

5915 - Filters and Networks

Raytheon Company

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Current Rating Per Function In Amps

    7.5 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Maximum Temp Rise

    25.0 deg celsius

  • Maximum Voltage Drop Per Function

    1.2 volts ac 6th radio interference and 2.0 volts dc 6th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 4th radio interference 4th function and 200.0 volts dc 4th radio interference 4th function

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    7.5 3rd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • Operating Current Rating Per Function In Amps

    7.5 4th radio interference

  • Maximum Voltage Drop Per Function

    1.2 volts ac 1st radio interference and 2.0 volts dc 1st radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Operating Current Rating Per Function In Amps

    7.5 5th radio interference

  • Maximum Dielectric Withstanding Dc Voltage

    1.5 kilovolts at sea level

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Operating Current Rating Per Function In Amps

    7.5 6th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 5th radio interference 5th function and 200.0 volts dc 5th radio interference 5th function

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 1st radio interference 1st function and 200.0 volts dc 1st radio interference 1st function

  • Overall Length

    0.970 inches nominal

  • Input Terminal Manufacturer Code

    71468

  • Maximum Voltage Drop Per Function

    1.2 volts ac 3rd radio interference and 2.0 volts dc 3rd radio interference

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Body Material

    aluminum

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.062 inches nominal

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 3rd radio interference 3rd function and 200.0 volts dc 3rd radio interference 3rd function

  • Maximum Voltage Drop Per Function

    1.2 volts ac 4th radio interference and 2.0 volts dc 4th radio interference

  • Features Provided

    moisture resistant and shock resistant

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Overall Width

    1.328 inches maximum

  • Full Load Insertion Loss Frequencies In Megahertz

    1.0 and 10.0 and 100.0 and 0.0 and 0.1 and 1000.0

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Inclosure Type

    hermetically sealed

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 6th radio interference 6th function and 200.0 volts dc 6th radio interference 6th function

  • Overall Height

    1.328 inches maximum

  • Full Load Minimum Insertion Loss At Specified Frequency In Decibels

    8.0 and 30.0 and 60.0 and 10.0 and 45.0 and 60.0

  • Operating Current Rating Per Function In Amps

    7.5 1st radio interference

  • Output Terminal Identification

    mil-c-38999

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Body Surface Treatment

    cadmium

  • Precious Material

    gold and silver

  • Maximum Voltage Drop Per Function

    1.2 volts ac 5th radio interference and 2.0 volts dc 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Input Terminal Identification

    mil-c-38999

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.062 inches nominal

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Precious Material And Location

    contact surfaces gold and contact grounding spring silver

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Functional Terminal Type And Quantity

    32 friction w/grounding strap and pin input-output

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 2nd radio interference 2nd function and 200.0 volts dc 2nd radio interference 2nd function

  • Unthreaded Mounting Hole Diameter

    0.132 inches minimum and 0.140 inches maximum

  • Maximum Voltage Drop Per Function

    1.2 volts ac 2nd radio interference and 2.0 volts dc 2nd radio interference

  • Output Terminal Manufacturer Code

    71468

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Special Features

    thirty-two filtered functions

  • Vibration Resistance Range In Hertz

    +10.0/+500.0

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Style Designator

    filter connector

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...