MIL-C-39019/2

Circuit Breakers

CIRCUIT BREAKER

MIL-C-39019/2

5925-01-005-9798

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Contact Arrangement

    single pole,double throw

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.375 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Unpackaged Unit Weight

    50.0 grams

  • Thread Series Designator

    unef

  • Specification/Standard Data

    81349-mil-c-39019/2 government specification

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac and 500.0 dc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Body Length

    1.531 inches minimum and 1.562 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches minimum and 0.906 inches maximum

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Body Width

    0.594 inches minimum and 0.625 inches maximum

  • Case Material

    metal

  • Mounting Surface To Terminal End Distance

    1.669 inches minimum and 1.700 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes ac and 6.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac and 50.0 dc

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct and 0.950 maximum at 200 pct

  • Switch Terminal Type

    tab,solder lug

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Frequency In Hertz

    400.0

  • Test Data Document

    81349-mil-c-39019 specification

  • Terminal Type And Quantity

    2 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...