09M60-02-1-04N

Switches

SWITCH,ROTARY

09M60-02-1-04N

5930-01-008-4770

5930 - Switches

Grayhill Inc

SWITCH,ROTARY

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    data on certain environmental and performance

  • Contact Load Current Rating

    75.0 milliamperes resistive load ac at sea level

  • Overall Diameter

    0.761 inches minimum and 0.801 inches maximum

  • Contact Voltage Rating In Volts

    115.0 ac at sea level

  • Contact Switching Action

    breaks before makes each section rear

  • Overall Length

    1.855 inches minimum and 2.001 inches maximum

  • Err Default

    err default and err default

  • Nonturn Device Radius

    0.245 inches minimum at 3:00 o'clock and 0.275 inches maximum at 3:00 o'clock

  • Shaft Diameter

    0.123 inches minimum single actuator and 0.126 inches maximum single actuator

  • Test Data Document

    81349-mil-s-3786 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Switch Actuator Positioning Increment

    60.0 degrees single actuator

  • Contact Load Current Rating

    125.0 milliamperes resistive load dc at sea level

  • Switch Actuator Stop Device Type

    fixed stop single actuator

  • Individual Section Quantity

    2

  • Pole Quantity

    1 each section front

  • Nominal Thread Size

    0.250 inches single mounting facility

  • Shaft Flat/Slot Angular Location

    180.0 degrees from contact position 1 single actuator

  • Contact Voltage Rating In Volts

    28.0 dc at sea level

  • Rotor Through Connection Quantity

    1 each section

  • Thread Series Designator

    unef single mounting facility

  • Switch Contact Basic Design

    nonpile-up symmetrical

  • Operating Temp Range

    -65.0/+125.0 deg celsius

  • Terminal Type

    tab, solder lug

  • Flat Height

    0.084 inches minimum single actuator and 0.104 inches maximum single actuator

  • Throw Quantity

    4 each section rear

  • End Item Identification

    oliver perry class ffg, tarawa class lha, wasp class lhd, nimitz class cvn, supply class aoe, ticonderoga class cg (47), forrestal class cv. sonar acoustic miscellaneous.

  • Nonturn Device Type

    tab at 3:00 o'clock

  • Thread Class

    2a single mounting facility

  • Switch Actuator Indexing Position Quantity

    4 single actuator

  • First Flat Length

    0.230 inches minimum single actuator and 0.270 inches maximum single actuator

  • Shaft Length

    0.647 inches minimum single actuator and 0.727 inches maximum single actuator

  • Mounting Method

    threaded bushing single mounting facility

  • Hazardous Locations/Environmental Protection

    explosion proof

  • Shaft Type

    round, flatted single actuator

  • Special Features

    weapon system essential

  • Style Designator

    tap, circular, bushing mount

  • Criticality Code Justification

    feat

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...