913LMG3-35-28

Circuit Breakers

CIRCUIT BREAKER

913LMG3-35-28

5925-01-009-0195

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unc

  • Inclosure Protection Type For Which Designed

    explosion proof and shockproof and vibrationproof

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct and 7.000 maximum at 200 pct

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip

  • Trip Release Method

    magnetic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes dc

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    2.375 inches minimum and 2.515 inches maximum

  • Case Material

    plastic

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Body Style

    single pole type

  • Terminal Type And Quantity

    2 threaded stud

  • Test Data Document

    82577-918203 drawing

  • Unpackaged Unit Weight

    4.000 ounces

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    time delay

  • Circuit Protection Type

    overcurrent

  • Special Handling Feature

    magnetic

  • Arc Quenching Method

    magnetic blowout

  • Boss Height

    0.090 inches minimum and 0.165 inches maximum

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...