HE1B2-2-2

Circuit Breakers

CIRCUIT BREAKER

HE1B2-2-2

5925-01-011-9985

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    1.700 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Body Length

    1.562 inches maximum

  • Body Style

    2a single pole type

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.375 inches

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Terminal Type And Quantity

    2 wire hook

  • Bushing Length

    0.375 inches nominal

  • Body Width

    0.625 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct single location and 0.700 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Switch Terminal Type

    tab, solder lug

  • Switch Current Rating And Type In Amps

    1.0 ac and 0.5 dc

  • Unpackaged Unit Weight

    2.000 ounces

  • Thread Series Designator

    unef

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...