HM2-M3-1.5-A

Circuit Breakers

CIRCUIT BREAKER

HM2-M3-1.5-A

5925-01-012-9797

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    0.844 inches minimum and 0.906 inches maximum

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Bushing Length

    0.380 inches maximum

  • Nonturn Device Diameter

    0.109 inches minimum and 0.171 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Maximum Continuous Load Current Rating Per Pole

    1.5 amperes ac all locations

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches minimum and 0.656 inches maximum

  • Reset Method

    manual

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

  • Thread Series Designator

    unef

  • Body Width

    1.250 inches maximum

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct all locations and 0.550 maximum at 200 pct all locations

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    between pole one and two

  • Nonturn Device Length

    0.063 inches minimum and 0.125 inches maximum

  • Body Length

    1.500 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Body Style

    multipole-single actuator type

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Terminal Type And Quantity

    4 wire hook

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Nonturn Device Radius

    0.594 inches minimum and 0.656 inches maximum

  • Trip Release Method

    magnetic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...