106-P30-0,5A
Circuit Breakers
CIRCUIT BREAKER
106-P30-0,5A
E-T-A Elektrotechnische Apparate
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct single location and 40.000 maximum at 200 pct single location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location and 24.0 dc single location
-
Terminal Type And Quantity
2 tab, solder lug
-
Body Style
single pole type
-
Mounting Surface To Terminal End Distance
1.470 inches nominal
-
Frequency In Hertz
60.0 single location
-
Thread Series Designator
uns
-
Case Material
plastic
-
Body Length
0.750 inches nominal
-
Bushing Length
0.280 inches nominal
-
Trip Release Ambient Temp Rating
70.0 deg fahrenheit nominal single location
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Unpackaged Unit Weight
1.500 ounces
-
Manual Actuator Type And Quantity
1 push button
-
Nominal Thread Size
0.375 inches
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Arc Quenching Method
air
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Body Width
0.430 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
0.500 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3.0 ac single location and 3.0 dc single location
-
Thread Quantity Per Inch
27
-
Pole Quantity
1
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes ac single location and 500.0 milliamperes dc single location