JA2125W

Circuit Breakers

CIRCUIT BREAKER

JA2125W

5925-01-014-9857

5925 - Circuit Breakers

Westinghouse Electric Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.719 inches nominal

  • Pole Quantity

    2

  • Reset Method

    manual

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +625.0/+1250.0 ac all locations and +625.0/+1250.0 dc all locations

  • Features Provided

    adjustable trip release

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Body Length

    10.125 inches nominal

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Length

    8.875 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.125 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    8.438 inches nominal

  • Body Height

    4.062 inches nominal

  • Body Style

    multipole-single actuator type

  • Maximum Continuous Load Current Rating Per Pole

    125.0 amperes ac all locations and 125.0 amperes dc all locations

  • Terminal Type And Quantity

    4 compression

  • Boss Height

    0.250 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    22000.0 ac all locations and 10000.0 dc all locations

  • Body Width

    5.000 inches nominal

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Center To Center Distance Between Terminals Parallel To Width

    1.719 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Trip Delay Time In Seconds Per Rated Continuous Current

    500.000 maximum at 200 pct all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...